ÕÒÂÛÎÄÍø > ҽҩѧÂÛÎÄ > ҩѧÂÛÎÄ >

ÓлúÁ×ũҩ²ÐÁô¿ìËÙ¼ì²â·½·¨Ñо¿½øÕ¹(2)

¡¡¡¡5  Õ¹Íû

¡¡¡¡Ä¿Ç°Å©Ò©²ÐÁô¼ì²â£º·¢¹â¾ú¼¼ÊõÖ÷ÒªÓ¦ÓÃÓÚË®Öʼì²â¼°»·¾³¹æ»®£¬Ëæ×ż¼ÊõµÄ·¢Õ¹·¢¹â¾ú·¨½«ºÍµç×Ó¼¼ÊõÒÔ¼°¹âµç¼¼ÊõÏà½áºÏ£¬Öð²½·¢Õ¹ÎªÔÚÏß¼à²âϵͳ£¬ÎªÓлúÁ×ũҩÏÖ³¡¼à²âÌṩ¸ü¼Ó¿ìËٵļì²â·ÖÎöÊֶΡ£»¯Ñ§·¢¹âÊǽüÄêÀ´·¢Õ¹ÆðÀ´µÄÒ»ÖÖ¸ßÁéÃôµÄ΢Á¿¼°ºÛÁ¿ÓлúÁײÐÁô¼ì²â·ÖÎö¼¼Êõ£¬½ñºóÔڸĽøºÍÍêÉÆÔ­Óз¢¹âÊÔ¼ÁºÍÌåϵµÄͬʱ£¬Ð·¢¹âÊÔ¼ÁµÄºÏ³É¼°ÓëÆäËû¼¼Êõ(Èç΢Á÷¿ØÐ¾Æ¬¼¼Êõ¡¢´«¸ÐÆ÷¼¼ÊõµÈ)µÄÁªÓ㬸üÏÔʾ³ö»¯Ñ§·¢¹â·ÖÎö¼¼Êõ¿ìËÙ¡¢ÁéÃô¡¢¼ò±ãµÄÓŵ㡣ELISA¼¼ÊõÓëÉúÎï´«¸ÐÆ÷¼¼ÊõĿǰ»¹´¦ÓÚÆð²½½×¶Î£¬Ëæ×Å·ÖÎö¼¼ÊõµÄ²»¶Ï¸Ä½ø£¬ELISA¼õÉÙ½»²æ·´Ó¦µÄ·¢Éú£¬½øÒ»²½Ìá¸ßÁéÃô¶È¼°Îȶ¨ÐÔ£¬ÃâÒßÊÔ¼ÁºÐ²»¶ÏµÄÉÌÒµ»¯£»ÉúÎï´«¸ÐÆ÷µÄ¶à¹¦ÄÜ»¯(1¸ö´«¸ÐÆ÷¿É¼ì²â¶àÖÖũҩ²ÐÁô)£¬½µµÍ²úÆ·³É±¾£¬Ìá¸ßÁéÃô¶È¡¢Îȶ¨ÐÔºÍÑÓ³¤ÊÙÃü£¬ËüÃÇÔÚũҩ²ÐÁô¼ì²âÁìÓòÖлáµÃµ½½øÒ»²½µÄÓ¦ÓúÍÍÆ¹ã£¬Ê¹ÎÒ¹úµÄũҩ²ÐÁô¿ìËÙ¼ì²â¼¼ÊõµÄÓ¦ÓóöÏÖ¶àÔª»¯µÄ¾ÖÃæ¡£

¡¡¡¡²Î¿¼ÎÄÏ×

¡¡¡¡¡²1¡³  Thomtdka KW.Use of bioluminesecent bacterium photobacterium phosphoreum to detect potentially biohazardous materials in water£ÛJ£Ý.Bull Environ Contam Toxicol£¬1993,51(4)£º538.

¡¡¡¡¡²2¡³  Ô¬¶«ÐÇ£¬µËÓÀÖÇ£¬ÁÖÓñêÍ.Êß²ËÖÐÓлúÁ×ũҩ²ÐÁôµÄ·¢¹â¾ú¿ìËÙ¼ì²â£ÛJ£Ý.»·¾³»¯Ñ§,1997,16(1)£º77-81.

¡¡¡¡¡²3¡³  ÁèÔÆ£¬ÕÔÓå.·¢¹âϸ¾ú·¨ÔÚʳƷ°²È«ÐÔ¼ì²âÖеÄÓ¦ÓãÛJ£Ý.ʳƷÓëÉúÎï¼¼Êõѧ±¨,2005£¬24(6)£º106-110.

¡¡¡¡¡²4¡³  º«º×ÓÑ£¬ÓÎ×Óº­.»¯Ñ§·¢¹âÁªÓü¼ÊõÔÚÊÞÒ©²ÐÁô·ÖÎöÖеÄÓ¦ÓýøÕ¹£ÛJ£Ý.·ÖÎö¿ÆÑ§Ñ§±¨,2005£¬21(5)£º552-556.

¡¡¡¡¡²5¡³  Ayyagari MS£¬Kamtrkar S£¬Pande R£¬et al.Biosenors for pesticide detection based on alkaline phosphates catalyzed chemiluminescence£ÛJ£Ý.Materials Science and Engineering£¬1995£¬C2£º191-196.

¡¡¡¡¡²6¡³  ÈÄÖ¾Ã÷£¬Íõ½¨Äþ£¬ÀÜ.Á÷¶¯×¢É仯ѧ·¢¹â²â¶¨¼×»ù¶ÔÁòÁ×µÄÑо¿£ÛJ£Ý.·ÖÎö»¯Ñ§£¬2001£¬4£º1-5.

¡¡¡¡¡²7¡³  »Æè÷ƽ,Íõ½¨Äþ.ÀûÓû¯Ñ§·¢¹â¼¼Êõ¶ÔÓлúÁ×ũҩ½øÐмì²â·ÖÎö£ÛJ£Ý.Çຣʦ·¶´óѧѧ±¨£º×ÔÈ»¿ÆÑ§°æ£¬2003£¬(1)£º59-63.

¡¡¡¡¡²8¡³  Kumar M A,Chuhan R S£¬Thakur M S,et al.Automated flow enzyme-linked immunosorbent assay(ELISA)system for analysis of methyl parathion£ÛJ£Ý.Analytica Chimica Acta£¬2006£¬(560)£º30-34.

¡¡¡¡¡²9¡³  ÁõÊïÕÕ.¾ÅÊ®Äê´úũҩ²ÐÁô·ÖÎöм¼Êõ£ÛJ£Ý.ũҩ,1998£¬37(6)£º11-13.

¡¡¡¡¡²10¡³  Íõ¸Õ¶â£¬ºÎ·ïÉú£¬ÓãÌΣ¬µÈ.¼×»ù¶ÔÁòÁ×ELISA·ÖÎö·½·¨µÄ½¨Á¢¼°³õ²½Ó¦ÓãÛJ£Ý.Öйú¹¤ÒµÒ½Ñ§ÔÓÖ¾£¬2001£¬14(6)£º327-333.

¡¡¡¡¡²11¡³  ÕÔÈËÍõÕù£¬³Â¾°ºâ£¬Ñî¿¡.ÉúÎïø¼¼ÊõÓëøÃâÒß¼¼ÊõÔÚÅ©²Ð¿ìËÙ·ÖÎö·½ÃæµÄÓ¦ÓÃÓëÑо¿½øÕ¹£ÛJ£Ý.ÖйúÎÀÉú¼ìÑéÔÓÖ¾£¬2002,12(5):640-641.

¡¡¡¡¡²12¡³  º«Àö¾ý£¬¼ÖÃ÷ºê£¬Ç®´«·¶£¬µÈ.¼×»ù¶ÔÁòÁ׵ĸÁªÃâÒßÎü¸½·ÖÎö(ELISA)Ñо¿£ÛJ£Ý.ũҵ»·¾³Ñ§Ñ§±¨£¬2005,24£º187-190.

¡¡¡¡¡²13¡³  Nunes GS£¬Barcelo D.Electrochemicalbiosensors for pesticide determination in food samples£ÛJ£Ý.Pesticide Analysis£¬1998,26£º156-159.

¡¡¡¡¡²14¡³  Áõ×ÚÁÖ£¬ÅíÒå½».ÓлúÁ×´«¸ÐÆ÷µÄÑÐÖÆ£ÛJ£Ý.ʳƷ¿ÆÑ§£¬2004,25(2)£º130-134.

¡¡¡¡¡²15¡³  ÎÚÈÕÄÈ£¬À¿Æ.ÉúÎï´«¸ÐÆ÷ÔÚũҩ²ÐÁô·ÖÎöÖеÄÑо¿ÏÖ×´¼°Õ¹Íû£ÛJ£Ý.ʳƷÓë»úе,2005,21(2)£º54-76.

¡¡¡¡¡²16¡³  ³Â·«£¬ºÎÞÈ.ÓлúÁ×Ë®½âø´«¸ÐÆ÷¼°ÆäÓ¦ÓÃÑо¿½øÕ¹£ÛJ£Ý.´«¸ÐÆ÷¼¼Êõ£¬2004,23(4)£º5-9.

¡¡¡¡¡²17¡³  Wan Lixing£¬Li Renma.Portable fiber-optic immunosensor for detection of methsulfuron methyl£ÛJ£Ý.Talanta£¬2000£¬(52)£º879-883.

¡¡¡¡¡²18¡³  Mulchandani P£¬Chen W£¬Mulchandani A,et a1.Amperometricmicrobial biosensor for direct determination of organophosphate epesticides using recombinant microorganism with surface expressedorganophosphorus hydrolase£ÛJ£Ý.Biosensors & Bioelectronics£¬2001(16)£º433-437.

¹²2Ò³: ÉÏÒ»Ò³ [1] 2


ë±±©Â¶¶Ô´óÊóÆø¹Ü-Ö§Æø¹ÜÉÏÆ¤Ï¸°ûת»¯Ó°Ïì
ÌåÖÊÖ¸ÊýÓëÏ¥¹Ø½Ú¹ÇÐԹؽÚÑ×¹ØÏµ
¹¤É̹ÜÀí | ¹¤¿ÆÂÛÎÄ | ²ÆÎñ¹ÜÀí | ¹ÜÀíѧ | ¹«¹²¹ÜÀí | ²ÆÕþ˰ÊÕ | ֤ȯ½ðÈÚ | »á¼ÆÉó¼Æ | ¼ÆËã»ú | ·¨ÂÉÂÛÎÄ | ҽҩѧ | ººÓïÑÔÎÄѧ
Éç»áÂÛÎÄ | ¹¤¿ÆÂÛÎÄ | Àí¿ÆÂÛÎÄ | ÎÄ»¯ÂÛÎÄ | ÒÕÊõÂÛÎÄ | ÎÄѧÂÛÎÄ | ÕÜѧÂÛÎÄ | ÕþÖÎÂÛÎÄ | Ó¢ÓïÂÛÎÄ | д×÷Ö¸µ¼ | ¼ÆËã»úÓ¦ÓÃ
www.zlunwen.com ÕÒÂÛÎÄÍø ® °æÈ¨ËùÓÐ ÍøÕ¾µØÍ¼